{"product_id":"rojek-pk-bio-30-holzvergaserkessel-30-kw","title":"ROJEK PK BIO 30 wood gasification boiler 30 kW for logs","description":"\u003cp data-start=\"590\" data-end=\"914\"\u003eThe ROJEK PK BIO 30 is a high-performance wood gasification boiler with a nominal output of 30 kW for the efficient and low-emission heating of single-family homes, larger residential buildings, or workshops. It is designed for logs up to 530 mm in diameter and meets the requirements of EN 303-5 Class 5 as well as the Ecodesign Regulation.\u003c\/p\u003e  \u003chr data-start=\"916\" data-end=\"919\"\u003e  \u003ch2 data-start=\"921\" data-end=\"945\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"947\" data-end=\"1262\"\u003e⭐ 30 kW nominal power – ideal for larger detached houses\u003cbr data-start=\"1005\" data-end=\"1008\"\u003e⭐ 130 liter combustion chamber – long burn time of 5–9 hours\u003cbr data-start=\"1065\" data-end=\"1068\"\u003e⭐ Top loading – convenient and quick reloading\u003cbr data-start=\"1126\" data-end=\"1129\"\u003e⭐ Electronic control – precise combustion control\u003cbr data-start=\"1185\" data-end=\"1188\"\u003e⭐ EN 303-5 Class 5 \u0026amp; Ecodesign compliant – future-proof and standards-compliant\u003c\/p\u003e  \u003chr data-start=\"1264\" data-end=\"1267\"\u003e  \u003ch2 data-start=\"1269\" data-end=\"1299\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1301\" data-end=\"1601\"\u003eThe ROJEK PK BIO 30 is suitable for single-family and two-family homes with higher heating requirements, as well as smaller apartment buildings or commercial properties. It is designed for closed heating systems and operates particularly efficiently in combination with a sufficiently sized buffer storage tank.\u003c\/p\u003e  \u003chr data-start=\"1603\" data-end=\"1606\"\u003e  \u003ch2 data-start=\"1608\" data-end=\"1629\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"1631\" data-end=\"1826\"\u003eThanks to the top loading system, the combustion chamber is easy to fill. The generous 130-liter combustion chamber volume allows for longer burn times and reduces refueling intervals.\u003c\/p\u003e  \u003cp data-start=\"1828\" data-end=\"1986\"\u003eThe heat exchanger is cleaned via an external operating lever, which allows maintenance work to be carried out quickly and easily.\u003c\/p\u003e  \u003chr data-start=\"1988\" data-end=\"1991\"\u003e  \u003ch2 data-start=\"1993\" data-end=\"2017\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cp data-start=\"2019\" data-end=\"2222\"\u003eThe ROJEK PK BIO 30 operates according to the proven wood gasification principle. Combustion is regulated by an electronic control unit, which ensures a stable and efficient heat supply.\u003c\/p\u003e  \u003cp data-start=\"2224\" data-end=\"2348\"\u003eMaximum log length: 530 mm\u003cbr data-start=\"2256\" data-end=\"2259\"\u003ePermissible wood moisture content: maximum 20%\u003cbr data-start=\"2294\" data-end=\"2297\"\u003eRecommended calorific value of the fuel: 14–18 MJ\/kg\u003c\/p\u003e  \u003cp data-start=\"2350\" data-end=\"2486\"\u003eThe boiler meets the requirements of standard EN 303-5 class 5 for firewood and is Ecodesign compliant according to Regulation (EU) 2015\/1189.\u003c\/p\u003e  \u003chr data-start=\"2488\" data-end=\"2491\"\u003e  \u003ch2 data-start=\"2493\" data-end=\"2514\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"2516\" data-end=\"2625\"\u003eRated power: 30 kW\u003cbr data-start=\"2535\" data-end=\"2538\"\u003eEfficiency at rated power: 81.7%\u003cbr data-start=\"2575\" data-end=\"2578\"\u003eSeasonal space heating energy efficiency: 78%\u003c\/p\u003e  \u003cp data-start=\"2627\" data-end=\"2762\"\u003eThe emission values ​​correspond to class 5 according to EN 303-5 and meet the European Ecodesign requirements for solid fuels.\u003c\/p\u003e  \u003chr data-start=\"2764\" data-end=\"2767\"\u003e  \u003ch2 data-start=\"2769\" data-end=\"2788\"\u003eTechnical data\u003c\/h2\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"2790\" data-end=\"3128\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"2790\" data-end=\"2808\"\u003e  \u003ctr data-start=\"2790\" data-end=\"2808\"\u003e  \u003cth data-start=\"2790\" data-end=\"2800\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"2800\" data-end=\"2808\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"2828\" data-end=\"3128\"\u003e  \u003ctr data-start=\"2828\" data-end=\"2850\"\u003e  \u003ctd data-start=\"2828\" data-end=\"2841\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-start=\"2841\" data-end=\"2850\" data-col-size=\"sm\"\u003eROJEK\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2851\" data-end=\"2873\"\u003e  \u003ctd data-start=\"2851\" data-end=\"2860\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"2860\" data-end=\"2873\" data-col-size=\"sm\"\u003ePK BIO 30\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2874\" data-end=\"2908\"\u003e  \u003ctd data-start=\"2874\" data-end=\"2886\" data-col-size=\"sm\"\u003eBoiler type\u003c\/td\u003e  \u003ctd data-start=\"2886\" data-end=\"2908\" data-col-size=\"sm\"\u003ewood gasification boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2909\" data-end=\"2933\"\u003e  \u003ctd data-start=\"2909\" data-end=\"2924\" data-col-size=\"sm\"\u003eRated power\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2924\" data-end=\"2933\"\u003e30 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2934\" data-end=\"2961\"\u003e  \u003ctd data-start=\"2934\" data-end=\"2947\" data-col-size=\"sm\"\u003efuel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2947\" data-end=\"2961\"\u003efirewood\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2962\" data-end=\"2995\"\u003e  \u003ctd data-start=\"2962\" data-end=\"2985\" data-col-size=\"sm\"\u003eMax. log length\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2985\" data-end=\"2995\"\u003e530 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2996\" data-end=\"3023\"\u003e  \u003ctd data-start=\"2996\" data-end=\"3014\" data-col-size=\"sm\"\u003eFilling chamber volume\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3014\" data-end=\"3023\"\u003e130 l\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3024\" data-end=\"3049\"\u003e  \u003ctd data-start=\"3024\" data-end=\"3039\" data-col-size=\"sm\"\u003eefficiency\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3039\" data-end=\"3049\"\u003e81.7%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3050\" data-end=\"3080\"\u003e  \u003ctd data-start=\"3050\" data-end=\"3072\" data-col-size=\"sm\"\u003eSeasonal efficiency\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3072\" data-end=\"3080\"\u003e78%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3081\" data-end=\"3109\"\u003e  \u003ctd data-start=\"3081\" data-end=\"3088\" data-col-size=\"sm\"\u003estandard\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3088\" data-end=\"3109\"\u003eEN 303-5 Class 5\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3110\" data-end=\"3128\"\u003e  \u003ctd data-start=\"3110\" data-end=\"3122\" data-col-size=\"sm\"\u003eEcodesign\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3122\" data-end=\"3128\"\u003eYes\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"3130\" data-end=\"3133\"\u003e  \u003ch2 data-start=\"3135\" data-end=\"3150\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"3152\" data-end=\"3263\"\u003e  \u003cli data-start=\"3152\" data-end=\"3190\"\u003e  \u003cp data-start=\"3154\" data-end=\"3190\"\u003eROJEK PK BIO 30 wood gasification boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3191\" data-end=\"3218\"\u003e  \u003cp data-start=\"3193\" data-end=\"3218\"\u003eElectronic control\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3219\" data-end=\"3242\"\u003e  \u003cp data-start=\"3221\" data-end=\"3242\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3243\" data-end=\"3263\"\u003e  \u003cp data-start=\"3245\" data-end=\"3263\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"3265\" data-end=\"3268\"\u003e  \u003ch2 data-start=\"3270\" data-end=\"3293\"\u003eAccessories\/Recommendation\u003c\/h2\u003e  \u003cp data-start=\"3295\" data-end=\"3400\"\u003eA buffer storage tank is recommended for compliant and efficient operation.\u003cbr data-start=\"3377\" data-end=\"3380\"\u003eAlso useful:\u003c\/p\u003e  \u003cul data-start=\"3402\" data-end=\"3556\"\u003e  \u003cli data-start=\"3402\" data-end=\"3432\"\u003e  \u003cp data-start=\"3404\" data-end=\"3432\"\u003eThermal safety device\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3433\" data-end=\"3453\"\u003e  \u003cp data-start=\"3435\" data-end=\"3453\"\u003eReturn flow increase\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3454\" data-end=\"3500\"\u003e  \u003cp data-start=\"3456\" data-end=\"3500\"\u003eSafety group for solid fuel boilers\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3501\" data-end=\"3556\"\u003e  \u003cp data-start=\"3503\" data-end=\"3556\"\u003eSuitable buffer storage tank with sufficient volume\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"3558\" data-end=\"3561\"\u003e  \u003ch2 data-start=\"3563\" data-end=\"3596\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cp data-start=\"3598\" data-end=\"3895\"\u003eInstallation and commissioning must be carried out exclusively by a qualified specialist company.\u003cbr data-start=\"3702\" data-end=\"3705\"\u003eOnly untreated firewood with a maximum moisture content of 20% may be used.\u003cbr data-start=\"3796\" data-end=\"3799\"\u003eThe operation should be carried out in accordance with national regulations and in compliance with EN 303-5.\u003c\/p\u003e  \u003chr data-start=\"3897\" data-end=\"3900\"\u003e  \u003ch2 data-start=\"3902\" data-end=\"3908\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-start=\"3910\" data-end=\"3969\"\u003e\u003cstrong data-start=\"3910\" data-end=\"3944\"\u003eWhat is the permissible length of wood?\u003c\/strong\u003e\u003cbr data-start=\"3944\" data-end=\"3947\"\u003eFirewood up to 530 mm.\u003c\/p\u003e  \u003cp data-start=\"3971\" data-end=\"4022\"\u003e\u003cstrong data-start=\"3971\" data-end=\"4006\"\u003eWhat wood moisture content is permissible?\u003c\/strong\u003e\u003cbr data-start=\"4006\" data-end=\"4009\"\u003eMaximum 20%.\u003c\/p\u003e  \u003cp data-start=\"4024\" data-end=\"4141\"\u003e\u003cstrong data-start=\"4024\" data-end=\"4076\"\u003eDoes the boiler meet current environmental requirements?\u003c\/strong\u003e\u003cbr data-start=\"4076\" data-end=\"4079\"\u003eYes, it meets EN 303-5 Class 5 and the Ecodesign Regulation.\u003c\/p\u003e  \u003cp data-start=\"4143\" data-end=\"4239\"\u003e\u003cstrong data-start=\"4143\" data-end=\"4177\"\u003eHow long does a filling burn?\u003c\/strong\u003e\u003cbr data-start=\"4177\" data-end=\"4180\"\u003eApproximately 5–9 hours, depending on fuel quality and load.\u003c\/p\u003e  \u003cp data-start=\"4241\" data-end=\"4360\"\u003e\u003cstrong data-start=\"4241\" data-end=\"4281\"\u003eIs a buffer storage tank required?\u003c\/strong\u003e\u003cbr data-start=\"4281\" data-end=\"4284\"\u003eA buffer storage tank is recommended for efficient and standards-compliant operation.\u003c\/p\u003e  \u003cp data-start=\"4362\" data-end=\"4460\"\u003e\u003cstrong data-start=\"4362\" data-end=\"4392\"\u003eHow is the cleaning done?\u003c\/strong\u003e\u003cbr data-start=\"4392\" data-end=\"4395\"\u003eVia an external cleaning lever and a cleaning door.\u003c\/p\u003e  \u003chr data-start=\"4462\" data-end=\"4465\"\u003e  \u003ch2 data-start=\"4467\" data-end=\"4475\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"4477\" data-end=\"4704\"\u003eThe ROJEK PK BIO 30 is a high-performance, standards-compliant wood gasification boiler for medium to large heating requirements. It combines robust construction with modern emission compliance and efficient wood gasification technology.\u003c\/p\u003e","brand":"Rojek","offers":[{"title":"Default Title","offer_id":49423879242076,"sku":"RJPKB30","price":5751.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/holzvergaser-rojek-pk-bio-30-effizientes-heizen-mit-festen-brennstoffen-7239808.png?v=1770692556","url":"https:\/\/ie.gemashop.de\/products\/rojek-pk-bio-30-wood-gasification-boiler-30-kw","provider":"GEMA Shop","version":"1.0","type":"link"}