{"product_id":"gema-mdc-400-bundle-modul-heizstab-eehppv6-6-0-kw-400-v","title":"GEMA MDC 400 Heating Module + Heating Cartridge EEHPPV6 6.0 kW 400 V","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe GEMA MDC 400 Bundle Module + Heating Cartridge EEHPPV6 6.0 kW 400 V combines an MDC 400 heating module with a matching electric heating cartridge for central heating systems. The bundle is suitable for additional electric heat input into the heating circuit and supports existing primary heat generators in professionally installed systems.\u003c\/p\u003e \u003cp\u003eTypical application areas include supplementary heating, post-heating, frost protection support, emergency heat support, and the use of surplus PV electricity for heat input into the heating circuit. The design must match the respective system, the minimum flow rate, and the available electrical connection capacity.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe MDC 400 module forms the hydraulic base body for the heating circuit. It is designed for water or a suitable glycol mixture up to 50% concentration, features 50 mm polyurethane foam thermal insulation, and is connected to the heating circuit via female threads G 1 1\/4 inch.\u003c\/p\u003e \u003cp\u003eThe electric heating cartridge EEHPPV6 operates at 6.0 kW at 3~ 400 V. It features 3-stage power selection, temperature control in the range of approx. 5 to 75 °C, and a safety temperature limiter against overheating.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe bundle offers a clear combination of heating module and matching electric heating cartridge. This makes it suitable for operators who want to add electric supplementary heat to the heating circuit without having to assemble the module and heating cartridge separately.\u003c\/p\u003e \u003cp\u003eThe manual power staging of the heating cartridge supports adapted operation when the full rated power is not required continuously. Especially in the context of a photovoltaic system, the stepwise power selection can be helpful when utilizing available electrical energy.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe MDC 400 module is integrated into the parallel heating circuit on the flow or return line of the main heat source. It is intended for open or closed central heating systems with appropriate safety devices.\u003c\/p\u003e \u003cp\u003eFor operation of the 6.0 kW version, a minimum flow rate of 343 l\/h must be ensured. An additional circulation pump is required and must be sized to suit the system. The safety valve, electrical protection, and control connection must be properly taken into account.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical data at a glance\u003c\/h2\u003e \u003cp\u003eThe following information refers to the specific bundle consisting of the MDC module and the matching electric heating cartridge.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBase module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eMDC 400\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating rod SKU\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eEEHPPV6\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRated power\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e6.0 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower consumption\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e6000 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e400 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePhases\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e3 phases\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFrequency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eCurrent draw\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e8.7 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eConnection type\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e3~ 400 V three-phase connection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating cartridge connection\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1 1\/2 inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eInstallation length of heating cartridge\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e520 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eUnheated area\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e100 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eTemperature range of heating cartridge\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 5 to 75 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eSafety temperature limiter\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 93 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMinimum flow rate\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e5.72 l\/min, equivalent to 343 l\/h\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eModule connection heating circuit\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/4 inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating cartridge connection module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/2 inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMedium\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eWater or suitable glycol mixture\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. glycol content\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 %\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eInsulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 mm polyurethane foam\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e10 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating temperature module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eModule length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e600 mm\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eAssembly\u003c\/h2\u003e \u003cp\u003eThe heating module is integrated into the parallel heating circuit on the flow or return line of the main heat source. Before switching on, the module and the system must be completely filled with water and vented.\u003c\/p\u003e \u003cp\u003eAssembly, electrical connection, and testing are tasks for qualified professionals. The minimum flow rate of 343 l\/h must be ensured; for this purpose, an additional circulation pump must be provided, which is operated together with the heating cartridge.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eDry running must be avoided, as it can cause damage to the heating element and lead to safety risks. The device may only be operated with suitable safety devices and a functioning safety valve.\u003c\/p\u003e \u003cp\u003eThe product information does not replace proper planning, heat load calculation, or electrical sizing. The safety valve, circulation pump, fuse protection, installation material, and control connection must be checked to match the system.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eMDC 400 heating module\u003c\/li\u003e \u003cli\u003eElectric heating cartridge EEHPPV6 \/ EJK maxi 6000 MR, 6.0 kW, 400 V\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Gema GmbH","offers":[{"title":"Default Title","offer_id":58079489360220,"sku":"MDC400+EEHPPV6","price":553.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/durchlauferhitzer-notheizung-mdc-400p-inkl-elektroheizstab-9-kw-4897799.webp?v=1770692302","url":"https:\/\/ie.gemashop.de\/products\/gema-mdc-400-bundle-module-heating-rod-eehppv6-6-0-kw-400-v","provider":"GEMA Shop","version":"1.0","type":"link"}