{"product_id":"gema-elektroheizpatrone-ejk-maxi-6000-mr-6-kw-pv-geeignet","title":"GEMA electric heating cartridge EJK maxi 6000 MR 6 kW PV-ready","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe electric heating cartridge 6 kW PV compatible EJK maxi 6000 MR is a three-phase heating cartridge for heating water in suitable metallic containers. It is suitable for domestic hot water tanks, buffer tanks, and applications in central heating systems when electric auxiliary or backup heating is required.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe heating cartridge is equipped with an insulated heating element, metal head, integrated temperature controller, and safety temperature limiter. The power is selected via a separate 3-stage rotary switch, allowing the heating output to be set to 2 kW, 4 kW, or 6 kW as needed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eWith manual power selection, the full heating output can be reduced when the complete rated power is not needed. This is particularly helpful in the context of a photovoltaic system, as the electric auxiliary heating can be better adapted to the available power.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe EJK maxi 6000 MR is intended for suitable open and closed metallic containers. It can be used in enameled and non-enameled metallic tanks, provided that the installation position, immersion depth, connection conditions, and operating limits are observed.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003cp\u003eThe following technical data refers to the 6 kW variant EJK maxi 6000 MR.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRated output\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e6.0 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e400 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePhases\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eConnection type\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eThree-phase \/ 3~ 400 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e10 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e75 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eConnection size\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1 1\/2 inch\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eMounting\u003c\/h2\u003e \u003cp\u003eMounting is intended horizontally or vertically with the thermostat pointing downward. The heating element and temperature sensor tube must be fully immersed in water, the sleeve may be at most approx. 100 mm long, and the terminal box of the rotary switch must remain accessible after installation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eThe heating cartridge may only be switched on once the tank is completely filled with water and vented. The electrical connection must be carried out by a qualified specialist; with hard or calcareous water, the heating element should be checked regularly and cleaned if necessary.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eGEMA electric heating cartridge EJK maxi 6000 MR 6 kW with separate 3-stage rotary switch\u003c\/li\u003e \u003cli\u003eFlat gasket Ø55 x Ø47.5 x 2 mm\u003c\/li\u003e \u003cli\u003eO-ring Ø46 x 3.5 mm\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Gema GmbH","offers":[{"title":"Default Title","offer_id":47730351931740,"sku":"EEHPPV6","price":397.73,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/heizpatrone-einstellbare-6-kw-elektroheizpatrone-pv-geeignet-6642259.png?v=1770692910","url":"https:\/\/ie.gemashop.de\/products\/gema-elektroheizpatrone-ejk-maxi-6000-mr-6-kw-pv-geeignet","provider":"GEMA Shop","version":"1.0","type":"link"}