{"product_id":"ibc-gk8k-oeko-32-kw-festbrennstoffkessel","title":"IBC GK-8K eco 32 kW solid fuel boiler pellet boiler","description":"\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e  \u003cdiv class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\" data-message-model-slug=\"gpt-5-2\" dir=\"auto\" data-message-id=\"e5e88de9-bf2e-44e4-a292-dfb1845d4992\" data-message-author-role=\"assistant\"\u003e  \u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[1px]\"\u003e  \u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e  \u003cp data-end=\"667\" data-start=\"388\"\u003eThe \u003cstrong data-end=\"415\" data-start=\"392\"\u003eIBC GK-8K eco 32 kW\u003c\/strong\u003e This is a modern solid fuel boiler for operation with pellets or pressed wood briquettes. With energy efficiency class A+ and a space heating annual efficiency of 82%, it is ideally suited for single-family and multi-family homes with higher heating requirements.\u003c\/p\u003e  \u003cp data-end=\"774\" data-start=\"669\"\u003eThe boiler meets the requirements of EU regulations 2015\/1187 and 2015\/1189 and is CE certified.\u003c\/p\u003e  \u003chr data-end=\"779\" data-start=\"776\"\u003e  \u003ch2 data-end=\"807\" data-start=\"781\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-end=\"1186\" data-start=\"809\"\u003e⭐  \u003cstrong data-end=\"838\" data-start=\"811\"\u003e32 kW nominal heat output\u003c\/strong\u003e – ideal for larger living spaces and renovation projects\u003cbr data-end=\"897\" data-start=\"894\"\u003e⭐  \u003cstrong data-end=\"928\" data-start=\"899\"\u003eEnergy efficiency class A+\u003c\/strong\u003e – high efficiency in continuous operation\u003cbr data-end=\"973\" data-start=\"970\"\u003e⭐  \u003cstrong data-end=\"1004\" data-start=\"975\"\u003eAutomatic heating mode\u003c\/strong\u003e – convenient setup\u003cbr data-end=\"1036\" data-start=\"1033\"\u003e⭐  \u003cstrong data-end=\"1076\" data-start=\"1038\"\u003eVery low auxiliary power consumption\u003c\/strong\u003e – only 0.050 kW at rated power\u003cbr data-end=\"1111\" data-start=\"1108\"\u003e⭐  \u003cstrong data-end=\"1158\" data-start=\"1113\"\u003eTested emission values ​​according to EU 2015\/1189\u003c\/strong\u003e – future-proof technology\u003c\/p\u003e  \u003chr data-end=\"1191\" data-start=\"1188\"\u003e  \u003ch2 data-end=\"1223\" data-start=\"1193\"\u003eDetailed description\u003c\/h2\u003e  \u003ch3 data-end=\"1258\" data-start=\"1225\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h3\u003e  \u003cp data-end=\"1525\" data-start=\"1260\"\u003eThe IBC GK-8K eco 32 kW is designed for use in residential buildings with medium to high heating demands. Typical applications include single-family homes with large living volumes, multi-family homes, or commercial buildings with pellet-based heating systems.\u003c\/p\u003e  \u003cp data-end=\"1688\" data-start=\"1527\"\u003eThe manufacturer recommends operation with a hot water storage tank with a minimum capacity of \u003cstrong data-end=\"1630\" data-start=\"1608\"\u003e640 liter volume\u003c\/strong\u003e (20 liters × 32 kW).\u003c\/p\u003e  \u003chr data-end=\"1693\" data-start=\"1690\"\u003e  \u003ch3 data-end=\"1722\" data-start=\"1695\"\u003eTechnology \u0026amp; equipment\u003c\/h3\u003e  \u003cp data-end=\"1980\" data-start=\"1724\"\u003eThe solid fuel boiler operates in \u003cstrong data-end=\"1790\" data-start=\"1761\"\u003eautomatic heating mode \u003c\/strong\u003eand is suitable for operation with \u003cstrong data-end=\"1904\" data-start=\"1857\"\u003ePressed wood in the form of pellets or briquettes\u003c\/strong\u003e designed as the preferred fuel.\u003c\/p\u003e  \u003cp data-end=\"2202\" data-start=\"1982\"\u003eAt nominal heat output, the boiler achieves a \u003cstrong data-end=\"2068\" data-start=\"2030\"\u003eFuel efficiency of 86.7%\u003c\/strong\u003e.\u003cbr data-end=\"2110\" data-start=\"2107\"\u003eAt 30% partial load, the efficiency is \u003cstrong data-end=\"2163\" data-start=\"2153\"\u003e85.6%\u003c\/strong\u003e.\u003c\/p\u003e  \u003cp data-end=\"2252\" data-start=\"2204\"\u003eThe electrical auxiliary power consumption is:\u003c\/p\u003e  \u003cul data-end=\"2470\" data-start=\"2254\"\u003e  \u003cli data-end=\"2326\" data-start=\"2254\"\u003e  \u003cp data-end=\"2326\" data-start=\"2256\"\u003e0.050 kW at nominal heat output\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"2395\" data-start=\"2327\"\u003e  \u003cp data-end=\"2395\" data-start=\"2329\"\u003e0.038 kW at 30% power\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"2470\" data-start=\"2396\"\u003e  \u003cp data-end=\"2470\" data-start=\"2398\"\u003e0.003 kW in standby mode\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-end=\"2475\" data-start=\"2472\"\u003e  \u003ch3 data-end=\"2501\" data-start=\"2477\"\u003eEfficiency \u0026amp; Environment\u003c\/h3\u003e  \u003cp data-end=\"2538\" data-start=\"2503\"\u003eThe IBC GK-8K eco 32 kW achieves:\u003c\/p\u003e  \u003cul data-end=\"2776\" data-start=\"2540\"\u003e  \u003cli data-end=\"2611\" data-start=\"2540\"\u003e  \u003cp data-end=\"2611\" data-start=\"2542\"\u003e\u003cstrong data-end=\"2571\" data-start=\"2542\"\u003eEnergy efficiency class A+\u003c\/strong\u003e\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"2690\" data-start=\"2612\"\u003e  \u003cp data-end=\"2690\" data-start=\"2614\"\u003e\u003cstrong data-end=\"2650\" data-start=\"2614\"\u003eEnergy Efficiency Index (EEI): 120\u003c\/strong\u003e\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"2776\" data-start=\"2691\"\u003e  \u003cp data-end=\"2776\" data-start=\"2693\"\u003e\u003cstrong data-end=\"2734\" data-start=\"2693\"\u003eAnnual space heating efficiency: 82%\u003c\/strong\u003e\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-end=\"2833\" data-start=\"2778\"\u003eEmission values ​​for the preferred fuel (pellets):\u003c\/p\u003e  \u003cul data-end=\"2952\" data-start=\"2835\"\u003e  \u003cli data-end=\"2859\" data-start=\"2835\"\u003e  \u003cp data-end=\"2859\" data-start=\"2837\"\u003eDust (PM): 14 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"2876\" data-start=\"2860\"\u003e  \u003cp data-end=\"2876\" data-start=\"2862\"\u003eOGC: 3 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"2894\" data-start=\"2877\"\u003e  \u003cp data-end=\"2894\" data-start=\"2879\"\u003eCO: 236 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"2952\" data-start=\"2895\"\u003e  \u003cp data-end=\"2952\" data-start=\"2897\"\u003eNOx: 88 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-end=\"3036\" data-start=\"2954\"\u003eThis means the device meets the requirements of the Ecodesign Regulation (EU) 2015\/1189.\u003c\/p\u003e  \u003chr data-end=\"3041\" data-start=\"3038\"\u003e  \u003ch3 data-end=\"3069\" data-start=\"3043\"\u003eStandards \u0026amp; conformity\u003c\/h3\u003e  \u003cp data-end=\"3121\" data-start=\"3071\"\u003eThe boiler complies with the following guidelines:\u003c\/p\u003e  \u003cul data-end=\"3266\" data-start=\"3123\"\u003e  \u003cli data-end=\"3163\" data-start=\"3123\"\u003e  \u003cp data-end=\"3163\" data-start=\"3125\"\u003eLow Voltage Directive 2006\/95\/EC\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"3194\" data-start=\"3164\"\u003e  \u003cp data-end=\"3194\" data-start=\"3166\"\u003eEMC Directive 2004\/108\/EC\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"3229\" data-start=\"3195\"\u003e  \u003cp data-end=\"3229\" data-start=\"3197\"\u003eMachinery Directive 2006\/42\/EC\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"3266\" data-start=\"3230\"\u003e  \u003cp data-end=\"3266\" data-start=\"3232\"\u003eEcodesign Directive 2009\/125\/EU\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-end=\"3335\" data-start=\"3268\"\u003eCE marking present.\u003c\/p\u003e  \u003chr data-end=\"3340\" data-start=\"3337\"\u003e  \u003ch2 data-end=\"3363\" data-start=\"3342\"\u003eTechnical data\u003c\/h2\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"4134\" data-start=\"3365\"\u003e  \u003cthead data-end=\"3383\" data-start=\"3365\"\u003e  \u003ctr data-end=\"3383\" data-start=\"3365\"\u003e  \u003cth class=\"\" data-col-size=\"sm\" data-end=\"3375\" data-start=\"3365\"\u003efeature\u003c\/th\u003e  \u003cth class=\"\" data-col-size=\"sm\" data-end=\"3383\" data-start=\"3375\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-end=\"4134\" data-start=\"3405\"\u003e  \u003ctr data-end=\"3437\" data-start=\"3405\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3418\" data-start=\"3405\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3437\" data-start=\"3418\"\u003eIBC Heating Technology\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3466\" data-start=\"3438\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3447\" data-start=\"3438\"\u003eModel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3466\" data-start=\"3447\"\u003eGK-8K eco 32 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3504\" data-start=\"3467\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3480\" data-start=\"3467\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3504\" data-start=\"3480\"\u003eSolid fuel boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3534\" data-start=\"3505\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3525\" data-start=\"3505\"\u003eNominal heat output\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3534\" data-start=\"3525\"\u003e32 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3566\" data-start=\"3535\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3560\" data-start=\"3535\"\u003eEnergy efficiency class\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3566\" data-start=\"3560\"\u003eA+\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3604\" data-start=\"3567\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3597\" data-start=\"3567\"\u003eEnergy Efficiency Index (EEI)\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3604\" data-start=\"3597\"\u003e120\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3647\" data-start=\"3605\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3639\" data-start=\"3605\"\u003eAnnual space heating efficiency\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3647\" data-start=\"3639\"\u003e82%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3690\" data-start=\"3648\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3680\" data-start=\"3648\"\u003eEfficiency at rated power\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3690\" data-start=\"3680\"\u003e86.7%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3730\" data-start=\"3691\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3720\" data-start=\"3691\"\u003eEfficiency at 30% load\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3730\" data-start=\"3720\"\u003e85.6%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3779\" data-start=\"3731\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3756\" data-start=\"3731\"\u003ePreferred fuel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3779\" data-start=\"3756\"\u003ePellets\/Pressed wood\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3829\" data-start=\"3780\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3817\" data-start=\"3780\"\u003eAuxiliary power consumption (rated power)\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3829\" data-start=\"3817\"\u003e0.050 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3871\" data-start=\"3830\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3859\" data-start=\"3830\"\u003eAuxiliary power consumption (30%)\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3871\" data-start=\"3859\"\u003e0.038 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3909\" data-start=\"3872\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3897\" data-start=\"3872\"\u003eStandby power consumption\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3909\" data-start=\"3897\"\u003e0.003 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3939\" data-start=\"3910\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3924\" data-start=\"3910\"\u003eHeating mode\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3939\" data-start=\"3924\"\u003eAutomatically\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3966\" data-start=\"3940\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3958\" data-start=\"3940\"\u003eCondensing boiler\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3966\" data-start=\"3958\"\u003eNo\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"3998\" data-start=\"3967\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3990\" data-start=\"3967\"\u003eCombined heat and power\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"3998\" data-start=\"3990\"\u003eNo\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"4024\" data-start=\"3999\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"4016\" data-start=\"3999\"\u003eCombination heater\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"4024\" data-start=\"4016\"\u003eNo\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"4051\" data-start=\"4025\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"4039\" data-start=\"4025\"\u003ePM emissions\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"4051\" data-start=\"4039\"\u003e14 mg\/m³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"4078\" data-start=\"4052\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"4067\" data-start=\"4052\"\u003eOGC emission\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"4078\" data-start=\"4067\"\u003e3 mg\/m³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"4106\" data-start=\"4079\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"4093\" data-start=\"4079\"\u003eCO emissions\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"4106\" data-start=\"4093\"\u003e236 mg\/m³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-end=\"4134\" data-start=\"4107\"\u003e  \u003ctd data-col-size=\"sm\" data-end=\"4122\" data-start=\"4107\"\u003eNOx emissions\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-end=\"4134\" data-start=\"4122\"\u003e88 mg\/m³\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-end=\"4139\" data-start=\"4136\"\u003e  \u003ch2 data-end=\"4158\" data-start=\"4141\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-end=\"4249\" data-start=\"4160\"\u003e  \u003cli data-end=\"4204\" data-start=\"4160\"\u003e  \u003cp data-end=\"4204\" data-start=\"4162\"\u003eSolid fuel boiler IBC GK-8K eco 32 kW\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"4228\" data-start=\"4205\"\u003e  \u003cp data-end=\"4228\" data-start=\"4207\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"4249\" data-start=\"4229\"\u003e  \u003cp data-end=\"4249\" data-start=\"4231\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-end=\"4254\" data-start=\"4251\"\u003e  \u003ch2 data-end=\"4281\" data-start=\"4256\"\u003eAccesories \u0026amp; Recommendation\u003c\/h2\u003e  \u003cp data-end=\"4330\" data-start=\"4283\"\u003eFor optimal operation, the following are recommended:\u003c\/p\u003e  \u003cul data-end=\"4510\" data-start=\"4332\"\u003e  \u003cli data-end=\"4363\" data-start=\"4332\"\u003e  \u003cp data-end=\"4363\" data-start=\"4334\"\u003eBuffer storage tank from 640 liters\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"4410\" data-start=\"4364\"\u003e  \u003cp data-end=\"4410\" data-start=\"4366\"\u003eSafety group for solid fuel boilers\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"4441\" data-start=\"4411\"\u003e  \u003cp data-end=\"4441\" data-start=\"4413\"\u003eThermal safety device\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"4475\" data-start=\"4442\"\u003e  \u003cp data-end=\"4475\" data-start=\"4444\"\u003eExhaust systems for pellet boilers\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-end=\"4510\" data-start=\"4476\"\u003e  \u003cp data-end=\"4510\" data-start=\"4478\"\u003ePellet storage and conveying systems\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-end=\"4515\" data-start=\"4512\"\u003e  \u003ch2 data-end=\"4552\" data-start=\"4517\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cp data-end=\"4716\" data-start=\"4554\"\u003eInstallation must be carried out exclusively by qualified personnel. Work on electrical components must be performed by a certified electrician.\u003c\/p\u003e  \u003cp data-end=\"4851\" data-start=\"4718\"\u003eThe installation room and the anteroom must be equipped with a suitable CO₂ warning device.\u003c\/p\u003e  \u003chr data-end=\"4856\" data-start=\"4853\"\u003e  \u003ch2 data-end=\"4866\" data-start=\"4858\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-end=\"4980\" data-start=\"4868\"\u003e\u003cstrong data-end=\"4904\" data-start=\"4868\"\u003eWhich fuel is permitted?\u003c\/strong\u003e\u003cbr data-end=\"4907\" data-start=\"4904\"\u003eThe boiler is designed for pressed wood in the form of pellets or briquettes.\u003c\/p\u003e  \u003cp data-end=\"5083\" data-start=\"4982\"\u003e\u003cstrong data-end=\"5022\" data-start=\"4982\"\u003eIs a buffer storage tank required?\u003c\/strong\u003e\u003cbr data-end=\"5025\" data-start=\"5022\"\u003eYes, a storage tank with a capacity of at least 640 liters is recommended.\u003c\/p\u003e  \u003cp data-end=\"5144\" data-start=\"5085\"\u003e\u003cstrong data-end=\"5138\" data-start=\"5085\"\u003eWhat energy efficiency class does the device achieve?\u003c\/strong\u003e\u003cbr data-end=\"5141\" data-start=\"5138\"\u003eA+.\u003c\/p\u003e  \u003cp data-end=\"5192\" data-start=\"5146\"\u003e\u003cstrong data-end=\"5184\" data-start=\"5146\"\u003eIs the boiler a condensing boiler?\u003c\/strong\u003e\u003cbr data-end=\"5187\" data-start=\"5184\"\u003eNo.\u003c\/p\u003e  \u003cp data-end=\"5253\" data-start=\"5194\"\u003e\u003cstrong data-end=\"5241\" data-start=\"5194\"\u003eWhat is the power consumption in standby mode?\u003c\/strong\u003e\u003cbr data-end=\"5244\" data-start=\"5241\"\u003e0.003 kW.\u003c\/p\u003e  \u003cp data-end=\"5341\" data-start=\"5255\"\u003e\u003cstrong data-end=\"5301\" data-start=\"5255\"\u003eDoes the boiler meet the ecodesign requirements?\u003c\/strong\u003e\u003cbr data-end=\"5304\" data-start=\"5301\"\u003eYes, according to EU 2015\/1187 and 2015\/1189.\u003c\/p\u003e  \u003chr data-end=\"5346\" data-start=\"5343\"\u003e  \u003ch2 data-end=\"5358\" data-start=\"5348\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"5589\" data-start=\"5360\"\u003eThe IBC GK-8K eco 32 kW is a powerful, EU-compliant pellet boiler with high efficiency and tested emission values. A reliable solution for modern biomass heating systems in the higher output range.\u003c\/p\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003c\/div\u003e","brand":"IBC","offers":[{"title":"Default Title","offer_id":47431926448476,"sku":"1108-32-1000","price":9082.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/pelletheizung-ibc-gk8k-oko-32-kw-4347734.png?v=1770692873","url":"https:\/\/ie.gemashop.de\/hr\/products\/ibc-gk8k-oeko-32-kw-solid-fuel-boiler","provider":"GEMA Shop","version":"1.0","type":"link"}