{"product_id":"rojek-pk-bio-49-holzvergaserkessel-49-kw","title":"ROJEK PK BIO 49 wood gasification boiler 49 kW for logs","description":"\u003cp data-start=\"575\" data-end=\"884\"\u003eThe ROJEK PK BIO 49 is a high-performance wood gasification boiler with a nominal output of 49 kW, suitable for larger residential buildings, apartment buildings, and commercial or agricultural properties. It is designed for logs up to 530 mm in diameter and meets the requirements of EN 303-5 Class 5 and the Ecodesign Regulation.\u003c\/p\u003e  \u003chr data-start=\"886\" data-end=\"889\"\u003e  \u003ch2 data-start=\"891\" data-end=\"915\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"917\" data-end=\"1237\"\u003e⭐ 49 kW nominal output – suitable for high heat demands\u003cbr data-start=\"970\" data-end=\"973\"\u003e⭐ 180 liter combustion chamber – long burn time of 5–9 hours\u003cbr data-start=\"1030\" data-end=\"1033\"\u003e⭐ Top loading – convenient filling with firewood\u003cbr data-start=\"1091\" data-end=\"1094\"\u003e⭐ Electronic control – controlled and efficient combustion\u003cbr data-start=\"1162\" data-end=\"1165\"\u003e⭐ EN 303-5 Class 5 \u0026amp; Ecodesign compliant – standards-compliant and low-emission\u003c\/p\u003e  \u003chr data-start=\"1239\" data-end=\"1242\"\u003e  \u003ch2 data-start=\"1244\" data-end=\"1274\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1276\" data-end=\"1421\"\u003eThe ROJEK PK BIO 49 is designed for larger single-family homes, multi-family homes, commercial buildings or agricultural applications.\u003c\/p\u003e  \u003cp data-start=\"1423\" data-end=\"1610\"\u003eIt is suitable for central heating systems with higher power requirements and is recommended for efficient operation in combination with a sufficiently sized buffer storage tank.\u003c\/p\u003e  \u003chr data-start=\"1612\" data-end=\"1615\"\u003e  \u003ch2 data-start=\"1617\" data-end=\"1638\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"1640\" data-end=\"1758\"\u003eThe generous combustion chamber volume of 180 liters allows for longer burning times and reduces refueling intervals.\u003c\/p\u003e  \u003cp data-start=\"1760\" data-end=\"1894\"\u003eThe top loading mechanism makes filling considerably easier, especially when using logs up to 530 mm in length.\u003c\/p\u003e  \u003cp data-start=\"1896\" data-end=\"2048\"\u003eThe heat exchanger is cleaned via an external operating lever, making maintenance work quick and easy.\u003c\/p\u003e  \u003chr data-start=\"2050\" data-end=\"2053\"\u003e  \u003ch2 data-start=\"2055\" data-end=\"2079\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cp data-start=\"2081\" data-end=\"2220\"\u003eThe ROJEK PK BIO 49 operates according to the proven wood gasification principle with electronic control to optimize the combustion process.\u003c\/p\u003e  \u003cp data-start=\"2222\" data-end=\"2346\"\u003eMaximum log length: 530 mm\u003cbr data-start=\"2254\" data-end=\"2257\"\u003ePermissible wood moisture content: maximum 20%\u003cbr data-start=\"2292\" data-end=\"2295\"\u003eRecommended calorific value of the fuel: 14–18 MJ\/kg\u003c\/p\u003e  \u003cp data-start=\"2348\" data-end=\"2479\"\u003eThe boiler meets the requirements of EN 303-5 Class 5 for firewood and is Ecodesign compliant according to Regulation (EU) 2015\/1189.\u003c\/p\u003e  \u003chr data-start=\"2481\" data-end=\"2484\"\u003e  \u003ch2 data-start=\"2486\" data-end=\"2507\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"2509\" data-end=\"2530\"\u003eRated power: 49 kW\u003c\/p\u003e  \u003cp data-start=\"2532\" data-end=\"2691\"\u003eThe ROJEK PK BIO 49 meets the emission requirements of class 5 according to EN 303-5 and complies with the European Ecodesign requirements for solid fuel boilers.\u003c\/p\u003e  \u003chr data-start=\"2693\" data-end=\"2696\"\u003e  \u003ch2 data-start=\"2698\" data-end=\"2717\"\u003eTechnical data\u003c\/h2\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"2719\" data-end=\"3000\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"2719\" data-end=\"2737\"\u003e  \u003ctr data-start=\"2719\" data-end=\"2737\"\u003e  \u003cth data-start=\"2719\" data-end=\"2729\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"2729\" data-end=\"2737\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"2757\" data-end=\"3000\"\u003e  \u003ctr data-start=\"2757\" data-end=\"2779\"\u003e  \u003ctd data-start=\"2757\" data-end=\"2770\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-start=\"2770\" data-end=\"2779\" data-col-size=\"sm\"\u003eROJEK\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2780\" data-end=\"2802\"\u003e  \u003ctd data-start=\"2780\" data-end=\"2789\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"2789\" data-end=\"2802\" data-col-size=\"sm\"\u003ePK BIO 49\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2803\" data-end=\"2837\"\u003e  \u003ctd data-start=\"2803\" data-end=\"2815\" data-col-size=\"sm\"\u003eBoiler type\u003c\/td\u003e  \u003ctd data-start=\"2815\" data-end=\"2837\" data-col-size=\"sm\"\u003ewood gasification boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2838\" data-end=\"2862\"\u003e  \u003ctd data-start=\"2838\" data-end=\"2853\" data-col-size=\"sm\"\u003eRated power\u003c\/td\u003e  \u003ctd data-start=\"2853\" data-end=\"2862\" data-col-size=\"sm\"\u003e49 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2863\" data-end=\"2890\"\u003e  \u003ctd data-start=\"2863\" data-end=\"2876\" data-col-size=\"sm\"\u003efuel\u003c\/td\u003e  \u003ctd data-start=\"2876\" data-end=\"2890\" data-col-size=\"sm\"\u003efirewood\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2891\" data-end=\"2924\"\u003e  \u003ctd data-start=\"2891\" data-end=\"2914\" data-col-size=\"sm\"\u003eMax. log length\u003c\/td\u003e  \u003ctd data-start=\"2914\" data-end=\"2924\" data-col-size=\"sm\"\u003e530 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2925\" data-end=\"2952\"\u003e  \u003ctd data-start=\"2925\" data-end=\"2943\" data-col-size=\"sm\"\u003eFilling chamber volume\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2943\" data-end=\"2952\"\u003e180 l\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2953\" data-end=\"2981\"\u003e  \u003ctd data-start=\"2953\" data-end=\"2960\" data-col-size=\"sm\"\u003estandard\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2960\" data-end=\"2981\"\u003eEN 303-5 Class 5\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2982\" data-end=\"3000\"\u003e  \u003ctd data-start=\"2982\" data-end=\"2994\" data-col-size=\"sm\"\u003eEcodesign\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2994\" data-end=\"3000\"\u003eYes\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"3002\" data-end=\"3005\"\u003e  \u003ch2 data-start=\"3007\" data-end=\"3022\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"3024\" data-end=\"3135\"\u003e  \u003cli data-start=\"3024\" data-end=\"3062\"\u003e  \u003cp data-start=\"3026\" data-end=\"3062\"\u003eROJEK PK BIO 49 wood gasification boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3063\" data-end=\"3090\"\u003e  \u003cp data-start=\"3065\" data-end=\"3090\"\u003eElectronic control\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3091\" data-end=\"3114\"\u003e  \u003cp data-start=\"3093\" data-end=\"3114\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3115\" data-end=\"3135\"\u003e  \u003cp data-start=\"3117\" data-end=\"3135\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"3137\" data-end=\"3140\"\u003e  \u003ch2 data-start=\"3142\" data-end=\"3165\"\u003eAccessories\/Recommendation\u003c\/h2\u003e  \u003cp data-start=\"3167\" data-end=\"3232\"\u003eFor compliant and efficient operation, the following are recommended:\u003c\/p\u003e  \u003cul data-start=\"3234\" data-end=\"3386\"\u003e  \u003cli data-start=\"3234\" data-end=\"3287\"\u003e  \u003cp data-start=\"3236\" data-end=\"3287\"\u003eBuffer storage with corresponding storage volume\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3288\" data-end=\"3308\"\u003e  \u003cp data-start=\"3290\" data-end=\"3308\"\u003eReturn flow increase\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3309\" data-end=\"3339\"\u003e  \u003cp data-start=\"3311\" data-end=\"3339\"\u003eThermal safety device\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3340\" data-end=\"3386\"\u003e  \u003cp data-start=\"3342\" data-end=\"3386\"\u003eSafety group for solid fuel boilers\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"3388\" data-end=\"3391\"\u003e  \u003ch2 data-start=\"3393\" data-end=\"3426\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cp data-start=\"3428\" data-end=\"3534\"\u003eInstallation and commissioning must be carried out exclusively by a qualified specialist company.\u003c\/p\u003e  \u003cp data-start=\"3536\" data-end=\"3734\"\u003eOnly untreated firewood with a maximum moisture content of 20% may be used. Operation must be carried out in accordance with applicable national regulations and EN 303-5.\u003c\/p\u003e  \u003chr data-start=\"3736\" data-end=\"3739\"\u003e  \u003ch2 data-start=\"3741\" data-end=\"3747\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-start=\"3749\" data-end=\"3797\"\u003e\u003cstrong data-start=\"3749\" data-end=\"3783\"\u003eWhat is the permissible length of wood?\u003c\/strong\u003e\u003cbr data-start=\"3783\" data-end=\"3786\"\u003eUp to 530 mm.\u003c\/p\u003e  \u003cp data-start=\"3799\" data-end=\"3911\"\u003e\u003cstrong data-start=\"3799\" data-end=\"3846\"\u003eDoes the boiler meet current environmental standards?\u003c\/strong\u003e\u003cbr data-start=\"3846\" data-end=\"3849\"\u003eYes, it meets EN 303-5 Class 5 and the Ecodesign Regulation.\u003c\/p\u003e  \u003cp data-start=\"3913\" data-end=\"4020\"\u003e\u003cstrong data-start=\"3913\" data-end=\"3947\"\u003eHow long does a filling burn?\u003c\/strong\u003e\u003cbr data-start=\"3947\" data-end=\"3950\"\u003eApproximately 5–9 hours, depending on fuel quality and operating conditions.\u003c\/p\u003e  \u003cp data-start=\"4022\" data-end=\"4147\"\u003e\u003cstrong data-start=\"4022\" data-end=\"4062\"\u003eIs a buffer storage tank required?\u003c\/strong\u003e\u003cbr data-start=\"4062\" data-end=\"4065\"\u003eA buffer storage tank is recommended for efficient and compliant operation.\u003c\/p\u003e  \u003cp data-start=\"4149\" data-end=\"4201\"\u003e\u003cstrong data-start=\"4149\" data-end=\"4185\"\u003eWhat wood moisture content is permissible?\u003c\/strong\u003e\u003cbr data-start=\"4185\" data-end=\"4188\"\u003eMaximum 20%.\u003c\/p\u003e  \u003cp data-start=\"4203\" data-end=\"4318\"\u003e\u003cstrong data-start=\"4203\" data-end=\"4252\"\u003eHow is the heat exchanger cleaned?\u003c\/strong\u003e\u003cbr data-start=\"4252\" data-end=\"4255\"\u003eVia an external cleaning lever and a maintenance door.\u003c\/p\u003e  \u003chr data-start=\"4320\" data-end=\"4323\"\u003e  \u003ch2 data-start=\"4325\" data-end=\"4333\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"4335\" data-end=\"4565\"\u003eThe ROJEK PK BIO 49 is a high-performance wood gasification boiler for larger heating requirements. It combines robust construction, user-friendly operation, and emission standards for economical heating with logs.\u003c\/p\u003e","brand":"Rojek","offers":[{"title":"Default Title","offer_id":49423944352092,"sku":"RJPKB50","price":7470.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/holzvergaserkessel-rojek-pk-bio-50-kw-effiziente-warme-fur-feste-brennstoffe-1353047.png?v=1770692619","url":"https:\/\/ie.gemashop.de\/fi\/products\/rojek-pk-bio-49-wood-gasification-boiler-49-kw","provider":"GEMA Shop","version":"1.0","type":"link"}