Welcome to the GEMA Shop – your expert for heating, solar, and plumbing technology since 1991. We provide personal consultation and offer technical solutions.
  • fast shipping

  • Free help and advice

  • Open 7 days a week

+49 (0)39262 8787 - 20/21/23/12 *** sales@gema-net.de *** WhatsApp. +49(0)17660429928

Atmos  |  SKU: 01.05.20

Atmos GS 20 20 kW Wood Gasification Boiler

20 kW nominal output for classic log wood heating systems

Wood gasification technology with extraction fan and ceramic combustion chamber

A+ and boiler class 5 for a technically clean appliance class

The Atmos GS 20 is a hand-fed wood gasification boiler for logs with a nominal output of 20 kW, designed for heating single-family homes and similar properties. It combines classic wood gasification technology with an induced draft fan, ceramic combustion chamber, and intended integration into a buffer storage system.

Normal price 4.624,47 €
vAT included. Shipment will be charged at checkout.


Nimi: Jaroslav Cankař a syn ATMOS

Osoite: elenského 487 294 21 Bělá pod Bezdězem, Cr

Sähköposti: info@atmos-zentrallager.de

Verkkosivusto: https://www.atmos.eu/de/

Eurooppalainen valmistaja: Kyllä

Highlights

Rated Output 20 kW
Efficiency 91,4 %
Log Length 330 mm
Draft Requirement 20 Pa
Energy Efficiency Class A+

Hand-fed hot water boiler for split logs

Exhaust fan for assisted and even combustion

Ceramic-lined secondary combustion chamber

Large loading opening measuring 450 x 310 mm

Standard electromechanical control and thermostat logic

Description

Product Overview & Application

The Atmos GS 20 wood gasification boiler is a manually fed hot water heating boiler for split logs, designed for heating single-family homes and similar properties. The unit operates on the wood gasification principle with an exhaust fan, which supports stable combustion and controlled heat output typical of this design. With a nominal output of 20 kW, this model is suitable for systems requiring a classic log boiler with clear, robust technology.

Technology & Features

The boiler is designed for burning dry split logs. Combustion occurs using the downdraft gasification principle with an exhaust fan. The boiler body is made of steel sheets, and the secondary combustion chamber is equipped with ceramic components. Features include a boiler thermostat, flue gas thermostat, flow temperature thermometer, main switch, and mechanical operation of the start-up flap. A cooling loop is also included for protection against overheating.

Everyday Advantages

In practical operation, the Atmos GS 20 offers robust and straightforward boiler technology without unnecessary complexity. The large combustion chamber allows the use of split logs up to 330 mm in length. The wood gasification principle with preheated primary and secondary air supports even flame formation. Users will also appreciate the clear control layout, good accessibility for cleaning, and the electromechanical control system tailored to this boiler type.

System Integration & Compatibility

The Atmos GS 20 should be integrated into a professionally planned heating system with a buffer tank. The documentation explicitly recommends installation with a buffer tank and Laddomat 22 or a suitable return temperature boosting system to maintain the minimum return temperature and ensure clean operation. A minimum return temperature of 65 °C must be maintained for the boiler circuit, with the flow temperature set between 80 and 90 °C. For boiler outputs of 15 to 25 kW, pipe connections to buffer tanks should be made using 28x1 mm copper or 25 mm steel pipes.

Technical Specifications at a Glance

The following technical data for the Atmos GS 20 is clearly documented in the available materials.

Nominal Output 20 kW
Fuel Wood
Combustion Technology Wood Gasification
Efficiency 91.4 %
Energy Efficiency Class A+
Max. Flow Temperature 90 °C
Max. Operating Pressure 2.5 bar
Log Length 330 mm
Boiler Class 5
Draft Requirement 20 Pa
Flue Gas Temperature 134.7 °C
Flue Pipe Connection 150/152 mm
Safety Heat Exchanger Yes
Buffer Tank Recommended Yes
Height 1260 mm
Width 680 mm
Depth 845 mm
Voltage 230 V
Frequency 50 Hz
Power Consumption 50 W

Installation

Installation must be carried out in accordance with applicable regulations and based on professional system planning. The boiler must be placed in a boiler room with an adequate supply of combustion air; for systems between 15 and 75 kW, the documentation specifies a combustion air opening of at least 350 cm². A foundation dimension of 700 x 600 mm is recommended for the GS 20. The connection to the chimney must be professionally executed, and the flue pipe connection should be as short as possible, rising, and no longer than 1 m.

Notes

Only dry split logs or chopped wood with a residual moisture content of 12 to 20 % should be used for operation. Fresh or overly damp wood impairs combustion and can negatively affect performance, consumption, and the lifespan of the boiler and chimney. When lighting the fire, set the flue gas thermostat to 0 °C; during operation, set it to the normal working range. According to the documentation, the boiler thermostat should be set to approximately 85 to 90 °C. Operation, connection, and electrical work must be carried out by qualified personnel.

Scope of Delivery

  • Atmos GS 20 Wood Gasification Boiler
  • Steel Brush with Accessories
  • Poker
  • Fill Valve
  • Operating and Maintenance Manual
  • Honeywell FR 124 Draft Regulator
  • Ash Pan

payment & Security

Payment options

  • American Express
  • Apple Pay
  • Bancontact
  • BLIK
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store or access your credit card information.

Contact us